PV1-F AC 0.6/1.0kV (DC 1.8kV) XLPO insulation XLPO sheath PV cable
Application:
PV1-F cable is suitable for the series connection between PV modules and modules, the parallel connection between groups and between groups and DC distribution box (combiner box), and the connection between DC distribution box and inverter. Ac photovoltaic cable is suitable for the connection between inverter to step-up transformer, the connection between the step-up transformer to power distribution equipment, power distribution equipment to the power grid or the connection between the users.

Construction:
1. Conductor - Flexible tinned annealed class 5 copper
2. Insulation - Cross-linked polyolefins (XLPO)
3. Sheath - Cross-linked polyolefins (XLPO)
Cross Section:
1C1.5~35mm2
Temperature characteristics:
Ambient temperature:-40℃~+90℃
Max. temperature at conductor: 120 °C
The cables are intended to operate at ambient temperature until 90°C. For this a temperature index of 120°C applies to the insulation and the sheath, based on EN 60216-1 (20.000h, 50% residual elongation).
Cable laying temperature:≥-25℃
Minimum Bending Radius
6x Outer Ø
Electrical Characteristics:
Rated voltage: AC 0.6/1.0kV (DC 1.8kV)
High voltage test: 6.5kV / 5min
Color:
Insulation: Black
Sheath:Black or Red
Standard:
Cable design: 2 Pfg 1169/08.2007












Our cables are generally packed in wooden drums, steel-wooden drums, or steel drums. For cables of shorter lengths or smaller sizes, coil packaging on pallets is also available.